Wire Size Calculator

BIJLIBEE CABLE DESIGN TOOL

Wire Size Calculator

Load current, derating, voltage drop aur short-circuit check ke saath cable size estimate karein.

Safety First: Yeh preliminary estimate hai, installation instruction nahi. Final cable, breaker, earthing aur protection qualified electrical engineer/electrician se verify karayein.

Circuit Details Bharein

Available data select karein
Balanced three-phase assumed
kW, motor shaft/useful load
Line voltage
AC load only
Used in kW mode
Percent of load current
Metres
Resistance and ampacity table
Temperature rating
Generic adjustment factor
Air-reference estimate
Grouping derating
Equal length and termination assumed
Percent
kA; zero skips fault check
Seconds; used only when fault current is entered
Values ya design limits check karein. Calculator table range ke andar suitable cable nahi dhoondh saka.

PRELIMINARY RECOMMENDED PHASE CONDUCTOR

4 mm2 Copper

1 run per phase | PVC | Conduit / Enclosed

All selected checks passed
Calculated Load Current17.18 A
Design Current21.48 A
Corrected Capacity22.62 A
Suggested Breaker20 A
Estimated Voltage Drop4.24 V / 1.02%
Conductor Resistance5.23 Ohm/km at operating temp
Estimated Cable Loss242.00 W
Combined Derating Factor0.870
Required Size by Ampacity4 mm2
Required Size by Voltage Drop1.5 mm2
Required Size by Fault CheckSkipped
Preliminary Earth Conductor4 mm2

Wire size kaise select hota hai?

Professional cable selection mein load current ke saath ambient temperature, grouped circuits, installation method, conductor material, insulation, voltage drop aur short-circuit withstand sab dekhe jate hain. Calculator corrected cable capacity ko design current se bada rakhta hai aur standard sizes mein agla suitable option choose karta hai. Pure ghar ka load calculate karke main wiring size janne ke liye hamara Home Load Calculator use karein.

1. Load CurrentkW, phase, PF aur efficiency
2. AmpacityDerating ke baad capacity
3. Voltage DropLength aur conductor resistance
4. Fault CheckOptional adiabatic estimate

Important limitations

  • Generic ampacity tables aur correction factors use kiye gaye hain; exact cable construction tables alag ho sakte hain.
  • Harmonics, neutral loading, soil thermal resistivity, buried depth, solar heating, motor starting voltage drop aur termination limits separately verify karein.
  • Breaker/RCD/RCBO, cable cores, armour, earthing system aur fire-rating ka final design is tool se nahi hota.

Electrical current aur load samajhne ke liye Ampere to Watt Calculator dekhein, aur ghar ka bijli bill manage karne ke liye Ghar Ka Bijli Bill Kam Karne Ke Tarike guide padhein.

FAQs

Wire size sirf ampere se choose kar sakte hain?

Nahi. Cable length, voltage drop, temperature, grouping, installation, fault current aur cable construction bhi zaroori hain.

Copper aur aluminium cable mein kya difference hai?

Same cross-section par copper ki resistance aam taur par kam hoti hai. Aluminium termination, minimum size aur installation requirements alag ho sakte hain.

3% voltage drop hamesha rule hai?

Nahi. Acceptable limit circuit type, installation standard, source aur equipment requirements par depend karti hai. Input field mein project limit use karein.

Kya calculator ka breaker aur earth size final hai?

Nahi. Ye preliminary indication hai. Protection coordination, disconnection time, earthing system aur local code ke liye engineer se verify karayein.

Disclaimer: Cable ampacity tables manufacturer, number of cores, installation method aur standard ke hisaab se badalti hain. Is estimate par bina professional verification ke wiring purchase ya install na karein.